top of page
Blockage Inspectors

Boiler Not Firing Up for Central Heating: Troubleshooting Guide

A boiler failing to fire up for central heating can be a frustrating and inconvenient issue, especially during colder months. At Blockage Inspectors, we understand the importance of a properly functioning boiler for a comfortable home. In this comprehensive troubleshooting guide, we'll walk you through the steps to diagnose and potentially resolve the problem of a boiler not firing up for central heating. Let's get to the bottom of this issue!



boiler
Call Blockage Inspectors, your plumber in Enfield for free advice

Step 1: Check the Thermostat


Start by checking the thermostat settings. Ensure it is set to a temperature higher than the current room temperature and set to the "heating" mode. If your thermostat runs on batteries, replace them to ensure it is functioning correctly.


Step 2: Verify the Boiler Pressure


Low boiler pressure can cause the system to shut down as a safety measure. Check the boiler pressure gauge and ensure it falls within the recommended range (usually between 1 and 1.5 bar). If the pressure is too low, refer to the boiler's manual for instructions on how to increase it.


Step 3: Inspect the Pilot Light (for older boilers)


If you have an older boiler with a pilot light, check to see if it is still lit. If the pilot light has gone out, follow the manufacturer's instructions to relight it. Be cautious and follow safety guidelines while handling the pilot light.


Step 4: Reset the Boiler


Modern boilers often have a reset button or display code to indicate a fault. Try resetting the boiler by following the manufacturer's instructions. If the boiler continues to display an error code or does not reset, note down the code and consult the boiler's manual or a qualified engineer for further assistance.


Step 5: Check for Frozen Condensate Pipe


In freezing weather, the condensate pipe (a white plastic pipe connected to the boiler) can freeze, causing the boiler to shut down. Check the pipe for signs of freezing and carefully thaw it using warm water bottles or a cloth soaked in warm water. Once thawed, restart the boiler.


Step 6: Check Gas Supply and Valves


Ensure that the gas supply to the boiler is not interrupted. Check that the gas meter is on, and all relevant valves are open. If you suspect a gas supply issue, contact your gas supplier or a qualified engineer.


Step 7: Seek Professional Assistance


If you have followed the above steps and your boiler still does not fire up for central heating, it's best to seek professional assistance. Boiler issues can be complex, and a qualified engineer can diagnose the problem accurately and implement the necessary repairs.


By following these troubleshooting steps, you can identify and potentially resolve the issue of your boiler not firing up for central heating. However, if you encounter any challenges or need expert assistance, don't hesitate to contact our team at Blockage Inspectors. Our experienced engineers are ready to help you diagnose and rectify boiler issues, ensuring your home remains warm and comfortable throughout the year. Contact us today for reliable and efficient heating solutions!


5 views0 comments

Recent Posts

See All

Comments


CONTACT BLOCKAGE INSPECTORS NOW

Phone: 

07956645152

Address:

70 Bounces Rd, Enfield N9 8JS

Hours: 
Friday Open 24 hours
Saturday Open 24 hours
Sunday Open 24 hours
Monday Open 24 hours
Tuesday Open 24 hours
Wednesday Open 24 hours
Thursday Open 24 hours

bottom of page